Positive-Pressure Attack (PPA):
The use and application of high volume ventilation fans before fire
suppression that are intended to force heat and smoke toward desired exhaust openings.
تفاوت بین PPV و PPA ❓
💥💥مراحل اجرای تهویه فشار مثبت طبق کتاب Essentials of firefighting :
Step 1: Clear the intake opening of all obstructions.
Step 2: Ensure that any exhaust openings are larger than the intake
opening.
Step 3: Place the fan(s) near the intake opening.
NOTE:
The fan should be placed at the appropriate distance based on exhaust opening size and the manufacturer’s recommendation.
Step 4: Start the fan and temporarily direct it away from the opening.
Step 5: Direct the fan toward the intake opening.
Step 6:
Inspect the site to ensure the effectiveness of ventilation.
Step 7:
If the ventilation is ineffective, discontinue use of the fan.
Reevaluate the location or size of the intake and exhaust
openings and check for obstructions to the flow of air.
Step 8:
Inspect fans and document results before returning them to
service.
💥 کتاب ضروریات آتش نشانی:
محصول انجمن بین المللی آموزش های آتش نشانی (IFSTA)
💥 تعداد فصول : ۲۷
💥 تعداد صفحات: ۱۵۰۰
♻️ کتاب مذبور با توجه به جامعیت و پوشش نسبتا کامل مطالب تخصصی، به عنوان یکی از منابع اصلی در شرکت های نفتی و موسسات* آموزش دوره های تخصصی آتش نشانی مورد استفاده قرار می گیرد.
💥 موقعیت گیری خودروهای آتش نشانی
✳️ کاری از سازمان آتش نشانی ارومیه
🔻🔻🔻🔻🔻🔻🔻🔻🔻
@ghaemi125